ce_mtu – Manages MTU settings on HUAWEI CloudEngine switches¶
New in version 2.4.
Parameters¶
Notes¶
Note
- Either
sysmtu
param is required orinterface
ANDmtu
params are req’d. state=absent
unconfigures a given MTU if that value is currently present.- Recommended connection is
network_cli
. - This module also works with
local
connections for legacy playbooks.
Examples¶
- name: Mtu test
hosts: cloudengine
connection: local
gather_facts: no
vars:
cli:
host: "{{ inventory_hostname }}"
port: "{{ ansible_ssh_port }}"
username: "{{ username }}"
password: "{{ password }}"
transport: cli
tasks:
- name: "Config jumboframe on 40GE1/0/22"
ce_mtu:
interface: 40GE1/0/22
jumbo_max: 9000
jumbo_min: 8000
provider: "{{ cli }}"
- name: "Config mtu on 40GE1/0/22 (routed interface)"
ce_mtu:
interface: 40GE1/0/22
mtu: 1600
provider: "{{ cli }}"
- name: "Config mtu on 40GE1/0/23 (switched interface)"
ce_mtu:
interface: 40GE1/0/22
mtu: 9216
provider: "{{ cli }}"
- name: "Config mtu and jumboframe on 40GE1/0/22 (routed interface)"
ce_mtu:
interface: 40GE1/0/22
mtu: 1601
jumbo_max: 9001
jumbo_min: 8001
provider: "{{ cli }}"
- name: "Unconfigure mtu and jumboframe on a given interface"
ce_mtu:
state: absent
interface: 40GE1/0/22
provider: "{{ cli }}"
Return Values¶
Common return values are documented here, the following are the fields unique to this module:
Status¶
- This module is not guaranteed to have a backwards compatible interface. [preview]
- This module is maintained by the Ansible Community. [community]
Authors¶
- QijunPan (@QijunPan)
Hint
If you notice any issues in this documentation, you can edit this document to improve it.